Key specifications at a glance

  • Technology: AGM VRLA, front terminal
  • Nominal rating: 12 V; 40–195 Ah (C10, 1.80 V/cell, 20 °C)
  • Design life: more than 12 years (very long design life)
  • Terminal: front; M6 or M8 thread, model dependent; for 19″ and 23″ cabinets
  • Standards: IEC 60896-21 and -22
  • Container: flame-retardant ABS, UL94 V-0

Applications

  • Telecom – backup power in 19-inch and 23-inch cabinets.
  • Industrial applications – backup power as a battery bank.
  • Motion applications (FIAMM's Motion application category)

FIT models

FIT models
Model Nominal capacity (C10, 1.80 V/cell, 20 °C) Distinguishing feature
12FIT40 40 Ah 105 × 280 × 198 mm, 13 kg
12FIT60 60 Ah 105 × 280 × 260 mm, 18 kg
12FIT101 101 Ah 108 × 395 × 275 mm, 33 kg
12FIT131 130 Ah 126 × 558 × 282 mm, 46 kg
12FIT150 150 Ah 126 × 558 × 282 mm, 49 kg
12FIT151 150 Ah 110 × 531 × 316 mm, 49 kg
12FIT180 180 Ah 126 × 531 × 321 mm, 57 kg
12FIT201 195 Ah 126 × 531 × 321 mm, 61 kg

Dimensions are listed in the brochure's Length × Width × Height column order; refer to the manufacturer's dimensional drawing for mounting orientation. All models are 12 V front-terminal blocks.

Technical specifications – FIT front-terminal battery

Technical specifications – FIT front-terminal battery
Parameter Value
Nominal voltage 12 V
Eurobat classification (brochure) >12 years, Very Long Life
Electrolyte sulfuric acid, specific gravity 1.3 at 20 °C, absorbed in glass microfiber (AGM) separators
Separator fiberglass separators to control recombination currents and avoid thermal runaway
Weight (typical) 12FIT40: 13 kg; 12FIT60: 18 kg; 12FIT101: 33 kg; 12FIT131: 46 kg; 12FIT150: 49 kg; 12FIT151: 49 kg; 12FIT180: 57 kg; 12FIT201: 61 kg
Front-terminal connection tin-plated copper connectors, ABS covers, special “L” clamp designed for the FIT range
Terminal torque M6: 7–9 Nm; M8: 10–12 Nm (by thread size)
Recommended float voltage 2.27 V/cell at 20 °C; temperature compensation: −2.5 mV/cell/°C (between −20 and +50 °C)
Typical float current approx. 0.6 mA/Ah (fully charged, 2.27 V/cell, 20 °C)
Boost (equalizing) charge 2.40 V/cell at 20 °C, max current limit 0.25 C10; stop at 0.001 C10 charging current or after 24 hours; recommended every 12 months
Recommended operating temperature 10–30 °C; operable from −20 to +50 °C, with reduced life expectancy above 20 °C
End-of-life criterion below 80% of nominal capacity
Gas recombination efficiency >98%
Safety valve opening pressure 0.15–0.30 atm (15–30 kPa)
Storage without refresh charge 9 months at 20 °C; 6 months at 30 °C; 3 months at 40 °C; refresh charge at the latest when the open-circuit voltage falls to 2.09 V/cell
Optimal storage conditions −10 to +30 °C, max 90% relative humidity
Parallel strings typically 4 (more depending on string voltage and cable length)
Remote venting system (RVS) optional add-on, front-side and top-side (does not replace ventilation)
Standards IEC 60896-21, IEC 60896-22, IEC 62485-2, IEC 60695-11-10, BS 6290-4, BS 6290-1
Case material flammability rating V-0 (UL 94 material test; BS 6334)

Source: FIAMM FIT brochure, Rev. 04.2026; FIAMM AGM (VRLA) engineering manual, edition 07/2026, Rev.16 (charging, temperature and storage data apply to the entire FIAMM AGM range). Specifications are subject to change by the manufacturer.

How to choose

Capacity and backup time

The eight FIT models cover 40 Ah (12FIT40) up to 195 Ah (12FIT201), at C10, 1.80 V/cell, 20 °C. Select the model from the load and the required backup time.

Installation dimensions

Block size can differ even at the same capacity: the 150 Ah 12FIT150 and 12FIT151 have different overall dimensions (126 × 558 × 282 mm and 110 × 531 × 316 mm, respectively). Choose between them based on the available installation space; refer to the manufacturer's dimensional drawing for mounting orientation.

Cabinet and terminals

The front-terminal design is made for 19-inch and 23-inch cabinets; blocks are connected with tin-plated copper connectors, ABS covers and a special “L” clamp designed for the FIT range. Thread size (M6 or M8) depends on the model.

Enclosed cabinets and temperature

Ventilation is mandatory in enclosed cabinets as well and must be sized per IEC 62485-2, which FIAMM lists as an applicable standard. An optional front-side or top-side remote venting system (RVS) is available as an add-on; it does not replace the sized ventilation, which is still required when an RVS is used. FIAMM recommends an operating temperature of 10–30 °C; above 20 °C, life expectancy is reduced.

How to choose
Situation Recommended model Why
Small telecom load, limited space 12FIT40 or 12FIT60 40 or 60 Ah, 13 or 18 kg
Mid-range capacity demand 12FIT101 or 12FIT131 101 or 130 Ah
150 Ah, matched to cabinet size 12FIT150 or 12FIT151 same capacity, different overall dimensions
Highest capacity from a single block 12FIT180 or 12FIT201 180 or 195 Ah

Related services and products

Energom Electronic Kft. is an official distributor of FIAMM. Energom sizes FIT battery banks to the load and backup time, handles installation and commissioning, and tracks battery condition through capacity testing. Services across the Central and Eastern European region; product delivery across Europe.

FAQ

What is the design life of the FIAMM FIT?

The FIAMM FIT has a design life of more than 12 years; the brochure gives a Eurobat classification of “>12 years, Very Long Life.” FIAMM defines end of life as capacity below 80% of the nominal value, and life expectancy is shorter at operating temperatures above 20 °C. Design life is a design figure, not a guaranteed service life; actual service life depends on operating temperature, charger settings and discharge frequency.

What cabinets do FIT batteries fit?

FIAMM FIT front-terminal blocks are made for 19-inch and 23-inch cabinets, with all connections accessible from the front. Overall dimensions for each model are listed in the model table.

What float voltage does the FIAMM FIT require?

For the FIAMM FIT, the FIAMM AGM engineering manual specifies a float voltage of 2.27 V/cell at 20 °C with −2.5 mV/cell/°C temperature compensation. The boost charge is 2.40 V/cell (20 °C) with a max current limit of 0.25 C10.

How long can FIT batteries be stored without recharging?

Per the FIAMM AGM engineering manual, FIAMM FIT blocks can be stored without recharging for up to 9 months at 20 °C, 6 months at 30 °C and 3 months at 40 °C. A refresh charge is due at the latest when the open-circuit voltage falls to 2.09 V/cell.

Request a quote

For an accurate quote, include the system voltage, the load, the required backup time, the cabinet type (19-inch or 23-inch) and the available installation space.

Request a Quote

We respond within 24 hours on business days.

Request a Callback