FIAMM FHT2 12 V, 95–180 Ah Front-Terminal VRLA AGM Battery
The FIAMM FHT2 is a 12 V front-terminal VRLA AGM battery block range rated 95–180 Ah (C10, 1.80 V/cell, 20 °C) for 19-inch and 23-inch cabinets. FIAMM designed the FHT2 for hot telecom and data center sites, with operating conditions up to 35 °C; the FHT2 design life is 7 years at 35 °C and 20 years at 20 °C, with a Eurobat Very Long Life (>12 years) classification.
Key specifications at a glance
- Technology: AGM VRLA, for operating conditions up to 35 °C
- Nominal rating: 12 V; 95–180 Ah (C10, 1.80 V/cell, 20 °C)
- Design life: 7 years at 35 °C (20 years at 20 °C); Eurobat Very Long Life (>12 years)
- Terminal: front, M8 female; for 19″ and 23″ cabinets
- Standards: IEC 60896-21 and -22
- Container: flame-retardant, high-tensile-strength ABS, UL94 V-0
Applications
- Telecom – backup power in 19-inch and 23-inch cabinets at sites with high ambient temperature.
- Data centers – backup power as a battery bank.
- Sites with reduced cooling – according to FIAMM, higher temperature tolerance helps save air-conditioning energy.
- Cyclic applications – including frequent charge and discharge.
- Motion applications (FIAMM's Motion application category)
FHT2 models
| Model | Nominal capacity (C10, 1.80 V/cell, 20 °C) | Dimensions (Length × Width × Height), weight |
|---|---|---|
| 12FHT102 | 95 Ah | 108 × 395 × 275 mm, 34 kg |
| 12FHT152 | 150 Ah | 110 × 531 × 316 mm, 50 kg |
| 12FHT182 | 180 Ah | 126 × 531 × 321 mm, 58 kg |
All three models are 12 V front-terminal blocks with M8 female terminals. Dimensions are listed in the brochure's Length × Width × Height column order; refer to the manufacturer's dimensional drawing for mounting orientation.
Technical specifications – FHT2 front-terminal battery
| Parameter | Value |
|---|---|
| Nominal voltage | 12 V |
| Electrolyte | sulfuric acid, specific gravity 1.3 at 20 °C, absorbed in glass microfiber (AGM) separators |
| Separator | microporous separators to control recombination currents and avoid thermal runaway |
| Weight (typical) | 12FHT102: 34 kg; 12FHT152: 50 kg; 12FHT182: 58 kg |
| Terminal torque | M8: 10–12 Nm |
| Recommended float voltage | 2.27 V/cell at 20 °C; temperature compensation: −2.5 mV/cell/°C (between −20 and +50 °C) |
| Typical float current | approx. 0.6 mA/Ah (fully charged, 2.27 V/cell, 20 °C) |
| Boost (equalizing) charge | 2.40 V/cell at 20 °C, max current limit 0.25 C10; stop at 0.001 C10 charging current or after 24 hours; recommended every 12 months |
| Recommended operating temperature (entire FIAMM AGM range) | 10–30 °C; life expectancy is reduced above 20 °C |
| Max operating temperature – FHT2 | peaks up to max 45 °C (FHT2-specific figure from the FIAMM engineering manual) |
| End-of-life criterion | below 80% of nominal capacity |
| Gas recombination efficiency | >98% |
| Safety valve opening pressure | 0.15–0.30 atm (15–30 kPa) |
| Storage without refresh charge | 9 months at 20 °C; 6 months at 30 °C; 3 months at 40 °C; refresh charge at the latest when the open-circuit voltage falls to 2.09 V/cell |
| Optimal storage conditions | −10 to +30 °C, max 90% relative humidity |
| Parallel strings | typically 4 (more depending on string voltage and cable length) |
| Maintenance | no water topping-up required (VRLA); battery condition (voltage, temperature, internal resistance, valve) must still be checked periodically per the manufacturer's instructions |
| Transport | non-hazardous per the manufacturer's classification; transportable by road, rail or air |
| Recyclability | 99% recyclable at end of life |
| Standards | IEC 60896-21, IEC 60896-22, IEC 62485-2, IEC 60695-11-10, BS 6290-4, BS 6290-1 |
| Case material flammability rating | V-0 (UL 94 material test; BS 6334) |
Source: FIAMM FHT2 brochure, Rev. 04.2026; FIAMM AGM (VRLA) engineering manual, edition 07/2026, Rev.16 (charging, temperature and storage data apply to the entire FIAMM AGM range). Specifications are subject to change by the manufacturer.
How to choose
Site temperature
The FHT2 is built for operating conditions up to 35 °C, and FIAMM states its design life at both 35 °C (7 years) and 20 °C (20 years). Where site cooling is limited, these two figures are a design starting point; replacement timing should be determined by capacity testing.
Required capacity
The range has three models: 95 Ah (12FHT102), 150 Ah (12FHT152) and 180 Ah (12FHT182), at C10, 1.80 V/cell, 20 °C. Select the capacity from the load and the required backup time.
Cabinet and terminals
The front-terminal design with M8 female terminals is made for 19-inch and 23-inch cabinets, keeping all connections accessible from the front. Check the available installation space against the dimensions in the model table; refer to the manufacturer's dimensional drawing for mounting orientation.
Charging at higher temperatures
FIAMM specifies −2.5 mV/cell/°C temperature compensation for the 2.27 V/cell (20 °C) float voltage. At warm sites, correct compensation settings are especially important to avoid overcharging.
| Situation | Recommended model | Why |
|---|---|---|
| Smaller telecom load, smaller cabinet | 12FHT102 | 95 Ah, 34 kg |
| Mid-range capacity demand | 12FHT152 | 150 Ah |
| Highest capacity from a single block | 12FHT182 | 180 Ah |
Related services and products
- Industrial batteries – the full industrial battery portfolio
- Battery maintenance – capacity testing, condition assessment and replacement planning
- DC power systems – 48 VDC solutions for telecom sites
- Uninterruptible power supply – backup power system design with battery banks
- 48 VDC systems
- UPS systems
- FIAMM FIT
- FIAMM Pure Guard (FPG)
- FIAMM FLB
Energom Electronic Kft. is an official distributor of FIAMM. Energom sizes FHT2 battery banks to the load, the backup time and the site temperature, handles installation and commissioning, and tracks battery condition through capacity testing. Services across the Central and Eastern European region; product delivery across Europe.
FAQ
What operating temperature can the FIAMM FHT2 handle?
The FIAMM FHT2 is designed for operating conditions up to 35 °C (with a design life of 7 years at 35 °C); according to the FIAMM engineering manual, the FHT2 allows peaks of up to 45 °C. The recommended operating range for the entire FIAMM AGM range is 10–30 °C, and life expectancy is reduced above 20 °C.
What is the FHT2 design life at high temperature?
FIAMM states a design life of 7 years at 35 °C and 20 years at 20 °C for the FHT2; the FHT2 carries a Eurobat Very Long Life (>12 years) classification. FIAMM defines end of life as capacity below 80% of the nominal value. Design life is a design figure, not a guaranteed service life; actual service life depends on operating temperature, charger settings and discharge frequency.
Can the FHT2 be used in cyclic operation?
Yes. According to FIAMM, the FIAMM FHT2 withstands frequent charge and discharge, so it suits cyclic applications as well as float standby service.
How long can the FHT2 be stored without recharging?
Per the FIAMM AGM engineering manual, the FIAMM FHT2 can be stored without recharging for up to 9 months at 20 °C, 6 months at 30 °C and 3 months at 40 °C. A refresh charge is due at the latest when the open-circuit voltage falls to 2.09 V/cell.
Request a quote
For an accurate quote, include the system voltage, the load, the required backup time, the cabinet type (19-inch or 23-inch) and the typical site temperature.
We respond within 24 hours on business days.