TAB e.motive 12–96 V LiFePO4 Traction Batteries
The TAB e.motive is a LiFePO4 (LFP) traction battery range for forklifts and industrial vehicles, built to custom voltage and capacity: 12–96 V, 50–1,400 Ah and 1.2–115.2 kWh. The batteries come in DIN or BS sizes designed to fit in place of lead-acid batteries, support fast and opportunity charging, and include an integrated TAB BMS with CAN and RS485 communication.
Key specifications at a glance
- Voltage, capacity, energy: 12–96 V; 50–1400 Ah; 1.2–115.2 kWh
- Cell chemistry: LiFePO4
- Cycle life: 2000 cycles (0.5C) / 3000 cycles (0.2C), 80% DoD
- Operating temperature: −20 to +55 °C operation; 0 to +50 °C charging
- Protection rating, socket: IP54 (IP65 optional); DIN 160 / 320 A
- Communication, certification: CAN, RS485; UN 38.3, IEC 62619
The cycle counts are manufacturer figures at 0.5C and 0.2C and 80% depth of discharge (DoD), not a guaranteed service life. TAB does not state an end-of-life capacity.
Applications
- Forklifts: lead-acid battery replacement in a plug-and-play design.
- Industrial and utility vehicles.
- Cleaning machines, cranes and lifts.
- Robots, industrial drones and light electric vehicles.
- Mining and agricultural equipment, trains and boats.
- Multi-shift operation with opportunity charging.
e.motive configurations
e.motive batteries are built to order for each vehicle; TAB does not publish a fixed list of model designations. The grouping below follows the TAB BMS architecture and the configurations listed in the catalog.
| Configuration | Nominal voltage | Key feature |
|---|---|---|
| TAB e.motive, 12 V | 12 V | single-unit BMS system, custom capacity |
| TAB e.motive, 24 V and 48 V | 24 V, 48 V | single-unit BMS system; configurations listed in the catalog: 24 V 200/400/450 Ah, 48 V 400/600 Ah |
| TAB e.motive, higher voltage (max 96 V) | max 96 V | master–slave BMS configuration for higher voltages; configurations listed in the catalog: 80 V 400/600/800 Ah |
Lithium traction battery technical specifications
| Parameter | Value |
|---|---|
| Cell chemistry | LiFePO4 |
| Voltage | 12–96 V |
| Capacity | 50–1,400 Ah |
| Energy | 1.2–115.2 kWh |
| Cycle life | 2,000 cycles (0.5C) / 3,000 cycles (0.2C), 80% DoD |
| Operating temperature | −20 to +55 °C operation; 0 to +50 °C charging |
| Storage temperature | −20 to +60 °C |
| Charging time | approx. 2 h fast charging, approx. 4 h normal charging (manufacturer figure; actual time depends on capacity and charger current) |
| Battery dimensions | DIN, BS, with additional counterweight, or custom; designed to fit in place of lead-acid batteries |
| Weight | custom; counterweight compartment for final weight adjustment |
| Protection rating | IP54 (IP65 optional) |
| Connector | DIN 160 / 320 A; dedicated charge and discharge main connectors |
| Battery management system (BMS) | integrated TAB BMS with LCD touch-screen display; data logger optional |
| BMS monitoring | cell voltage, cell temperature, cell resistance, battery current, BMS temperature, SOC and SOH calculation, remaining energy, time to full and time to empty |
| Cell balancing | passive, 1.3 A per cell |
| Protection functions | over-voltage, under-voltage, over-temperature, over-current, low-temperature charge protection, short-circuit protection; high-power contactors and fuses on the main power circuit |
| Communication | galvanically isolated RS-485 and CAN; CAN communication with the charger; galvanically isolated user-defined digital inputs and outputs |
| Charger | TAB Li-ion charger with CAN-controlled charging process |
| TAB charger range (rated charging current) | 24 V: 60, 100 and 200 A; 48 V: 50, 100, 150 and 200 A; 80 V: 100, 150, 200 and 225 A |
| Remote monitoring | TAB IoT Cloud: real-time remote monitoring via GSM, LTE or Wi-Fi, predictive diagnostics (additional function) |
| Service software | TAB Service Software: real-time data logging, parameter configuration, diagnostics, firmware updates |
| Additional functions | Sleep mode (automatic shutdown when idle); Lock mode (automatic shutdown at 1% SOC); LOWSOC digital output warning |
| Automatic fire suppression | aerosol-based system that activates automatically in thermal runaway (additional function) |
| Certification | UN 38.3 (modules and cells), IEC 62619; manufacturer quality management: ISO 9001 |
Source: TAB e.motive catalog, V6_02_2025; TAB e.motive manufacturer product page, November 2026. Specifications are subject to change by the manufacturer.
How to choose
- Voltage and BMS architecture: the vehicle sets the voltage (12–96 V). At 12, 24 and 48 V a single-unit BMS is used; higher-voltage batteries use a master–slave BMS configuration.
- Capacity and shift pattern: capacity is configurable from 50 to 1,400 Ah. TAB states approx. 2 hours with fast charging and approx. 4 hours with normal charging; actual charging time depends on the ratio of battery capacity to the selected charger current; in multi-shift operation, opportunity charging during breaks is also possible.
- Size and weight: the battery is built in DIN or BS sizes, with additional counterweight, or to custom dimensions, so it fits the existing lead-acid battery compartment. The counterweight compartment lets you set the weight the vehicle requires.
- Charger: charging is handled by a TAB Li-ion charger controlled over CAN; select the charging current from the charger range for the battery's voltage level.
- Environment: IP54 is standard, and IP65 is available for wet or dusty environments. The operating range is −20 to +55 °C, with charging permitted at 0 to +50 °C.
- Monitoring: the TAB IoT Cloud, available as an additional function, provides real-time remote monitoring and predictive diagnostics, while TAB Service Software handles data logging, parameter configuration and firmware updates.
Related services and products
- Industrial batteries – the full battery range by technology.
- Battery maintenance – periodic inspection; for LFP batteries, BMS data readout and cell balancing checks.
- TAB e.module L5.1 – rack-mount LFP module for stationary energy storage.
- TAB e.module H10.2 – series-connectable LFP module for commercial and industrial energy storage.
Energom Electronic Kft. is an official distributor of TAB. Services across the Central and Eastern European region; product delivery across Europe. Energom assesses the vehicle and shift requirements, configures the e.motive battery and charger, and handles commissioning and periodic maintenance.
FAQ
Can a TAB e.motive battery replace a forklift's lead-acid battery?
TAB e.motive batteries are built in DIN or BS sizes, with additional counterweight, or to custom dimensions, so they fit in place of the lead-acid battery. The counterweight compartment allows the final weight to match the vehicle's specification.
How long does it take to charge an e.motive battery?
TAB states a charging time for the e.motive of approx. 2 hours with fast charging and approx. 4 hours with normal charging; actual time depends on the ratio of battery capacity to the selected charger current. The battery also supports opportunity charging, so it can be charged during breaks in multi-shift operation.
What cycle life is the TAB e.motive rated for?
TAB specifies 2,000 cycles at 0.5C and 3,000 cycles at 0.2C, both at 80% depth of discharge. This is a manufacturer design figure, not a guaranteed service life.
What safety features does the e.motive battery have?
The TAB BMS protects against over-voltage, under-voltage, over-temperature, over-current, low-temperature charging and short circuits, with contactors and fuses on the main power circuit. An aerosol-based fire suppression system that activates automatically in thermal runaway is available as an additional function.
Request a quote
When requesting a quote, include the vehicle type, the required voltage and capacity, the size and weight of the current battery, the shift pattern and the available charging options.
We respond within 24 hours on business days.