Key specifications at a glance

  • Nominal rating, cell chemistry: 51.2 V / 100 Ah / 5.12 kWh; LFP
  • Cycle life: 6000 cycles (0.5C, 25 °C, 90% DoD)
  • Charge/discharge current: 50 A continuous; 102 A peak discharge (15 s)
  • Scalability: 16 modules per group (81.92 kWh); 6 groups with a Hub (491.52 kWh)
  • Communication, certification: CAN / RS485; CE, IEC 62619, UN38.3
  • Operating temperature: charge 0–45 °C; discharge −10–50 °C

Applications

  • Battery storage for off-grid power systems.
  • Backup power systems.
  • Uninterruptible supply in inverter-based systems.
  • Peak shaving with battery energy storage.
  • Residential energy storage, the product group in which Pytes lists the module.

E-BOX 48100R model and mounting options

The E-BOX 48100R is listed as a single model in the manufacturer's 2026 catalog. The mounting method depends on the Pytes accessory used; the enclosure ratings below apply to the cabinets, as Pytes does not state an IP rating for the module itself.

E-BOX 48100R model and mounting options
Pytes accessory Mounting Modules Enclosure rating
E BK1 floor bracket, stacked up to 6 modules –
R-BOX wall or floor box 2 modules IP20
VR-BOX-IC wall cabinet 2 modules IP20
Forest RB Plus floor cabinet 6 modules IP20
R-BOX-OC outdoor floor cabinet 4 modules IP55

LiFePO4 battery module specifications

LiFePO4 battery module specifications
Parameter Value
Nominal voltage 51.2 V
Voltage range 47.5–57.6 V
Nominal capacity 100 Ah
Nominal energy 5.12 kWh
Usable energy 4.608 kWh
Cell chemistry LFP (LiFePO4); automotive Grade A cells and in-house BMS, per the manufacturer
Recommended and max charge/discharge current 50 A (2.56 kW DC)
Peak discharge current 102 A (5.22 kW, 15 s)
Round-trip efficiency 95% (manufacturer figure; test conditions not stated)
Cycle life 6,000 cycles (0.5C, 25 °C, 90% DoD)
Scalability 16 modules per group in parallel (81.92 kWh); 6 groups with a Hub (491.52 kWh)
Communication CAN / RS485
Operating temperature charge 0–45 °C; discharge −10–50 °C
Ambient temperature −10 to 50 °C
Dimensions (L × W × H) with handle 480 × 658 × 117 mm (2.6U); without handle 435 × 620 × 117 mm
Weight 51 kg
Certification CE, IEC 62619, UN38.3

Source: Pytes E-BOX 48100R datasheet, V20241204; Pytes energy storage catalog, 2026 V1.1. Specifications are subject to change by the manufacturer.

How to choose

  • Power demand: the recommended and maximum continuous current of one module are both 50 A, which equals 2.56 kW DC; for 15 seconds the module can deliver 102 A, or 5.22 kW. Higher continuous loads require more modules in parallel, so the module count is set by whichever is stricter: power or energy. At 50 A the 100 Ah module runs at 0.5C, so it suits multi-hour discharge; short-duration, high-current loads need a higher module count.
  • Energy demand: each module has 5.12 kWh nominal and 4.608 kWh usable energy. Up to 16 modules (81.92 kWh) can be paralleled in one group; beyond that a Hub is required, which supports 6 groups (491.52 kWh).
  • Installation site: the 117 mm, 2.6U module fits a rack, a wall or a floor stand. For outdoor sites Pytes offers the IP55 R-BOX-OC cabinet; indoors the IP20 cabinets and brackets apply.
  • Temperature: the module charges at 0–45 °C and discharges at −10–50 °C. In unheated rooms, check winter charging conditions during system design.
  • Inverter compatibility: the module connects to the inverter over CAN and RS485; the protocol and supported inverter model are confirmed for each project.

Related services and products

Energom Electronic Kft. is an official distributor of Pytes. Services across the Central and Eastern European region; product delivery across Europe. Energom sizes the battery system, matches the module count to the inverter settings, and handles installation, commissioning and periodic maintenance.

FAQ

How many Pytes E-BOX 48100R modules can be connected in parallel?

Up to 16 Pytes E-BOX 48100R modules can be paralleled in one group, for 81.92 kWh of nominal energy. With a Hub, 6 groups can be combined for a total of 491.52 kWh.

How much continuous power does one E-BOX 48100R module deliver?

According to Pytes, the recommended and maximum continuous charge/discharge current are both 50 A, which equals 2.56 kW DC. Peak discharge is 102 A, or 5.22 kW, for 15 seconds.

Can the E-BOX 48100R be installed outdoors?

Pytes does not state an IP rating for the module. For outdoor installation, Pytes offers the IP55 R-BOX-OC cabinet, which holds 4 modules.

What communication does the E-BOX 48100R use with the inverter?

The Pytes E-BOX 48100R module has CAN and RS485 communication interfaces. Compatibility with the specific inverter model is checked as part of the quote.

Request a quote

When requesting a quote, include the inverter model, the required stored energy (kWh), the continuous and peak load power, the installation site (indoor or outdoor; rack, wall or floor stand) and the room temperature conditions.

Request a Quote

We respond within 24 hours on business days.

Request a Callback