Key specifications at a glance

  • Rated power: 350 kW DC total system power
  • Output voltage: 150–950 V DC; max 540 A with single output, 500 A (CCS2) with dual output
  • Connectors, simultaneous charging: 2 × CCS2, liquid-cooled; max 350 kW total or max 175 kW per outlet
  • OCPP: 1.6J
  • Certified metering: MID (Europe), LNE (France)
  • Protection rating, efficiency: IP55; IK10 (HMI IK07); peak efficiency >96% (power cabinet)

Applications

  • Fast charging corridors and highway rest stops: two vehicles charging on DC at the same time, up to 175 kW per outlet.
  • Fuel and service stations: the power cabinet can be placed separately from the dispenser.
  • Parking facilities and transit hubs: one dispenser with two CCS2 outlets.
  • Logistics fleets, fleet depots and fleet charging hubs: up to 350 kW total system power across two CCS2 outlets.

Delta High Power Charger 350 kW system components

Delta High Power Charger 350 kW system components
Unit Rating Distinguishing features
High Power Charger 350 kW (HPC350) – system 350 kW DC total system power Split architecture: power cabinet + dispenser with 2 × liquid-cooled CCS2 outlets (max 175 kW per outlet)
Power cabinet 380–415 V AC, three-phase; 565 A input current Peak efficiency >96%; IP55, IK10; 615 kg
Dispenser 150–950 V DC; max 540 A with single output 2 × CCS2 (4.5 m cable), 15-inch touch panel; 1,080 × 2,000 × 485 mm

DC ultra-fast charger technical specifications

DC ultra-fast charger technical specifications
Parameter Value
Rated power 350 kW DC total system power
Output voltage 150–950 V DC
Output current max 540 A with single output, 500 A (CCS2) with dual output
Connectors 2 × CCS2, liquid-cooled; max 350 kW total or max 175 kW per outlet
Dynamic power allocation Between the two CCS2 outlets from a single power cabinet, without additional hardware
Charging cable length 4.5 m
Cable management Integrated weighted retractor
Power cabinet: AC connection Three-phase (L1, L2, L3), delta connection; 380–415 V AC; 50 / 60 Hz
Power cabinet: input current 565 A
Power cabinet: power factor, THDi ≥ 0.99; THDi ≤ 5%
Power cabinet: peak efficiency >96%
Dispenser: supply DC+ and DC− (2 terminals per pole) from the power cabinet; auxiliary power: three-phase (L1, L2, L3), delta, 380–415 V AC, 50 / 60 Hz
Surge protection (SPD) Power cabinet: SPD Class II, Type 2; dispenser: SPD Class I + II, Type 2
Power cabinet: protection Overcurrent, undervoltage, overvoltage, residual current, surge protection, short circuit, over temperature, ground fault detection
Dispenser: output protection Overcurrent, undervoltage, overvoltage, surge protection, short circuit, over temperature, ground fault
User interface 15-inch LCD touch panel (4 buttons on HMI); emergency power off button; LED status light visible from a distance
Languages English (other languages available upon request)
Authentication, payment ISO/IEC 14443 A/B RFID reader; credit card reader (optional)
Network connectivity Cellular modem, Ethernet (RJ45)
Back-end protocol OCPP 1.6J
Certified metering MID (Europe), LNE (France)
Cooling Forced air (dispenser and power cabinet)
Dispenser dimensions (W × H × D) 1,080 × 2,000 × 485 mm (excluding plug and connector)
Weight Dispenser: 320 kg (excluding plug and connector); power cabinet: 615 kg
Protection rating Dispenser: IP55 (IEC 60529), IK10 (IEC 62262), HMI IK07; power cabinet: IP55, IK10
Operating temperature Dispenser: −30 °C to +50 °C (derating below +5 °C and above +45 °C); power cabinet: −30 °C to +50 °C (derating up to +60 °C)
Storage temperature −40 °C to +85 °C
Relative humidity < 95%, non-condensing
Altitude max 2,000 m
Dispenser compliance Safety: IEC 61851-1, IEC 61851-22, IEC 62479, IEC 61851-23; EMC: EN 55011, IEC 61851-21-2; accessibility: DIN 18040
Power cabinet certification CE, IEC 61851-1, IEC 61851-23

Source: Delta Electronics manufacturer product page (High Power Charger 350 kW, en-GB) and the two specification tables published on it (dispenser, power cabinet), December 2025. Specifications are subject to change by the manufacturer.

How to choose

Power sharing between two vehicles

The HPC350 feeds two liquid-cooled CCS2 outlets from one power cabinet: the two outlets deliver up to 350 kW combined, or up to 175 kW each when two vehicles charge at the same time. Output current is max 540 A with a single output and 500 A (CCS2) with dual output, so the power available per outlet also depends on the vehicle battery voltage and is lower at lower vehicle voltages. Power is allocated between the two outlets without additional hardware.

Grid connection

The power cabinet requires a 380–415 V AC three-phase (delta) connection with 565 A input current; the dispenser's auxiliary supply is also three-phase. Available grid capacity determines feasibility early in the project; across several chargers, the dynamic load management (DLM / load balancing) approach is defined in the project; the charger connects to the charge point management system (CPMS) via OCPP 1.6J.

Placement

In the split architecture, the dispenser (1,080 × 2,000 × 485 mm, 320 kg) stands at the parking bay, while the 615 kg power cabinet can be placed separately. The power cabinet is rated IP55 / IK10, both units are forced-air cooled, and the operating range is −30 °C to +50 °C, with dispenser derating below +5 °C and above +45 °C.

Certified metering, authentication and back end

Certified metering is MID (Europe) and LNE (France). Authentication uses an ISO/IEC 14443 A/B RFID reader, with an optional credit card reader; the charger connects to the back end via OCPP 1.6J over a cellular modem or Ethernet.

Related services and products

Energom Electronic Kft. is an official distributor of Delta Electronics. Energom assesses the site's grid supply, plans the placement of the power cabinet and dispenser, installs and commissions the system, configures the OCPP back-end connection, and carries out maintenance. Services across the Central and Eastern European region; product delivery across Europe.

FAQ

How many vehicles can charge at once on the Delta HPC350, and at what power?

Two vehicles can charge at the same time on the Delta HPC350's two liquid-cooled CCS2 outlets, at up to 175 kW each depending on vehicle voltage; the two outlets deliver up to 350 kW combined, also depending on vehicle voltage. Output current is max 540 A with a single output and 500 A (CCS2) with dual output.

Which OCPP version does the Delta HPC350 support?

For the Delta HPC350, the manufacturer specifies OCPP 1.6J; the charger connects to the charge point management system (CPMS) over a cellular modem or Ethernet (RJ45).

Is the Delta HPC350 MID-certified for metering?

For the Delta HPC350 DC energy metering system, the manufacturer specifies MID (Europe) and LNE (France).

What does the Delta HPC350 split architecture consist of?

The Delta HPC350 consists of a power cabinet (380–415 V AC, 565 A input current, peak efficiency >96%) and a separate dispenser that carries the two CCS2 outlets, the 15-inch touch panel and authentication. The dispenser receives DC power from the power cabinet.

Request a quote

For a quote, tell us the site's grid connection and available capacity, the planned locations of the power cabinet and dispenser, the number of vehicles charging at the same time, and your certified metering, payment and back-end requirements.

Request a Quote

We respond within 24 hours on business days.

Request a Callback