Key specifications at a glance

  • Rated AC power: 5–20 kW; max 5.5–22 kVA; 380/400 V, 3L/N/PE
  • DC input: max 1000 V; MPPT 150–900 V; 2 MPPTs (5–6 kW), 3 MPPTs (8–10 kW), 4 MPPTs (12–20 kW); 20 A per MPPT
  • Efficiency: max 98.2%, European 97.6% (5–10 kW); max 98.5%, European 98.0% (12–20 kW)
  • Battery: 40–60 V; Li-ion or lead-acid; max charge/discharge current 120–350 A
  • Backup operation: rated 5–20 kW; peak 10–40 kVA for 10 s if PV and battery power are sufficient; switchover <10 ms
  • Compliance, protection rating: EN 50549, VDE 4105, TOR Erzeuger Type A; IEC 62109-1/-2; IP66

Applications

  • Solar-plus-storage systems with self-consumption optimization, economy and backup modes.
  • Peak shaving by discharging the battery during demand peaks.
  • Time-of-use (TOU) tariff optimization with up to eight configurable 24-hour schedules.
  • Energy management for systems with a generator, heat pump and smart loads.
  • On-grid and off-grid system expansion through parallel operation of up to 10 inverters.

HIT G3 / G3S hybrid inverter models

Every model is available as a G3 (LED indicators) and a G3S (LCD screen) version with identical electrical data. Efficiency: max 98.2%, European 97.6% in the 5–10 kW group; max 98.5%, European 98.0% in the 12–20 kW group.

HIT G3 / G3S hybrid inverter models
Model Rated power Key differentiator
HIT-5L-G3 / -G3S 5 kW 2 MPPTs; battery max 120 A; natural convection
HIT-6L-G3 / -G3S 6 kW 2 MPPTs; battery max 150 A; natural convection
HIT-8L-G3 / -G3S 8 kW 3 MPPTs; battery max 190 A
HIT-10L-G3 / -G3S 10 kW 3 MPPTs; battery max 210 A
HIT-12L-G3 / -G3S 12 kW 4 MPPTs; battery max 250 A
HIT-15L-G3 / -G3S 15 kW 4 MPPTs; battery max 300 A
HIT-17L-G3 / -G3S 17 kW 4 MPPTs; battery max 350 A
HIT-20L-G3 / -G3S 20 kW 4 MPPTs; battery max 350 A; peak 40 kVA for 10 s

Hoymiles HIT G3 hybrid inverter specifications

Hoymiles HIT G3 hybrid inverter specifications
Parameter Value
Rated AC power 5 / 6 / 8 / 10 / 12 / 15 / 17 / 20 kW; max 5.5–22 kVA
Grid voltage, frequency 380/400 V, 3L/N/PE; range 266–480 V; 50/60 Hz
Rated / max output current rated 7.6–30.4 A, max 8.3–33.3 A (model dependent)
AC bypass max 50 A continuous; built-in meter
Unbalanced output 100% unbalanced output; max 50% of rated power per phase
Power factor, distortion > 0.99 (0.8 leading … 0.8 lagging); THDi < 3% at rated output; backup THDv < 3% at linear load
Max DC input voltage 1000 V
Rated and start-up DC voltage rated 720 V; start-up 150 V
MPPT voltage range 150–900 V
MPPTs / input strings 2 / 2 (5–6 kW); 3 / 3 (8–10 kW); 4 / 4 (12–20 kW); 1 string per MPPT
Max input current per MPPT 20 A
Max short-circuit current per MPPT 30 A
Recommended max PV power 10 / 12 / 16 / 20 / 24 / 30 / 34 / 40 kW (5 / 6 / 8 / 10 / 12 / 15 / 17 / 20 kW model); DC/AC ratio up to 200% (2:1)
Battery 40–60 V; Li-ion (charging self-adapting to BMS) or lead-acid (3-stage charging, equalization); CAN; external temperature sensor optional
Max charge and discharge current 120 / 150 / 190 / 210 / 250 / 300 / 350 / 350 A (5 / 6 / 8 / 10 / 12 / 15 / 17 / 20 kW model)
Backup operation rated 5–20 kW; peak 10–40 kVA for 10 s if PV and battery power are sufficient; switchover < 10 ms
Max efficiency 98.2% (5–10 kW); 98.5% (12–20 kW)
European efficiency 97.6% (5–10 kW); 98.0% (12–20 kW)
MPPT efficiency 99.9%
Max battery discharge to AC efficiency 95.7%
Protections anti-islanding; PV reverse polarity protection; insulation resistance detection; RCMU; AC overcurrent, short-circuit, over- and undervoltage protection; AFCI optional
Surge protection Type II DC / Type II AC
Protection rating IP66
Dimensions (W × H × D), weight 539 × 696 × 232 mm (excluding connectors and brackets); 41 kg
Operating temperature, humidity −25 to +65 °C (derating above 45 °C); 0–95%, non-condensing
Altitude ≤ 4000 m (derating above 2000 m)
Cooling natural convection (5–6 kW); smart fan (8–20 kW)
Topology solar side transformerless; battery side high-frequency isolation
User interface, digital I/O app, LED (G3) or LCD (G3S); DRM, 2 × DI, 2 × DO
Communication RS485; optional Wi-Fi, Ethernet or 4G
Parallel operation max 10 inverters, on-grid and off-grid; depending on the number of units, the manufacturer requires an external contactor for parallel systems
Energy management self-consumption, economy, backup, peak shaving and TOU modes; up to eight configurable 24-hour TOU schedules; generator, heat pump and smart load management
Grid compliance EN 50549; VDE 4105; TOR Erzeuger Type A; PN-EN 50549; SR EN 50549; RD 647; UNE 217001, 217002; G98; G99; IEC 62116; IEC 61727; IEC 61683; IEC 60068
Safety, EMC IEC 62109-1/-2; EN 61000-6-1/-2/-3/-4

Source: Hoymiles HIT Series datasheet (Global), REV1.8 (2026); Hoymiles EU product page (HIT-(5-20)L-G3), November 2026. Specifications are subject to change by the manufacturer.

How to choose

Power rating, MPPT count and efficiency

How to choose
Situation Suggested model Why
Two strings, fanless cooling preferred HIT-5L or HIT-6L (G3 / G3S) 2 MPPTs, natural convection
Three strings, 8–10 kW HIT-8L or HIT-10L (G3 / G3S) 3 MPPTs, 1 string per MPPT
Four strings, 12–20 kW HIT-12L, HIT-15L, HIT-17L or HIT-20L (G3 / G3S) 4 MPPTs; max 98.5%, European 98.0% efficiency

Recommended max PV power is twice the rated power (10–40 kW), with a DC/AC ratio of up to 200% (2:1).

Battery

  • The HIT range works with 40–60 V low-voltage batteries: with Li-ion, charging self-adapts to the BMS over CAN; with lead-acid, it uses 3-stage charging and equalization.
  • Max charge and discharge current is 120–350 A depending on the model, and the battery bank should be sized for that current.

Backup operation and load distribution

  • In backup operation, rated power is 5–20 kW and peak power is 10–40 kVA for 10 s if PV and battery power are sufficient; switchover takes less than 10 ms.
  • The output supports 100% unbalanced loading, up to 50% of rated power per phase.

Display and parallel systems

  • The G3 and G3S are electrically identical; the difference is LED indicators (G3) versus an LCD screen (G3S).
  • Up to 10 inverters can run in parallel on-grid and off-grid. Depending on the number of units, the manufacturer requires an external contactor for parallel systems; this should be specified during design from the current manufacturer documentation.

Related services and products

Energom Electronic Kft. is an official distributor of Hoymiles. Services across the Central and Eastern European region; product delivery across Europe. Energom handles hybrid inverter and battery bank sizing, installation, commissioning and energy management mode configuration.

FAQ

Which batteries work with the Hoymiles HIT G3 hybrid inverter?

The Hoymiles HIT-(5-20)L-G3 / G3S works with low-voltage Li-ion or lead-acid batteries in the 40–60 V range. Max charge and discharge current ranges from 120 A (HIT-5L) to 350 A (HIT-17L, HIT-20L) depending on the model.

What is the difference between the HIT G3 and G3S versions?

The Hoymiles HIT-(5-20)L-G3 has LED indicators and the G3S has an LCD screen; electrical data is identical across both versions.

Can the Hoymiles HIT G3 be paralleled?

Up to 10 Hoymiles HIT-(5-20)L-G3 / G3S inverters can be connected in parallel, in both on-grid and off-grid operation. Depending on the number of units, the manufacturer requires an external contactor for parallel systems; this should be specified during design from the current manufacturer documentation.

Does the HIT G3 support unbalanced loads?

The HIT-(5-20)L-G3 / G3S datasheet specifies 100% unbalanced output, with up to 50% of rated power on any one phase.

Request a quote

When requesting a quote, include the PV array power (and the string layout, if already available), the battery type, voltage and capacity, the loads to be supplied in backup operation and the energy management modes you plan to use.

Request a Quote

We respond within 24 hours on business days.

Request a Callback